TEH-38 Programmable, head-mount transmitter with galvanic insulation (0-10V output)
Product description
- output signal: 0 … 10 V
- galvanic input-output insulation
- programmable input signal range
- programmable sensor type: Pt100, Ni100, J, K, N, S, R, B, T
- RTD sensor can be connected in 2, 3 or 4-wire system
- internal or external compensation of thermocouple cold junction
- for mounting in B type connection heads
Technical data
Type of sensor, measuring range | programmable, see data sheet, table no.1 |
Maximum range, accuracy, thermal drift | see data sheet, table no.1 |
Pt100 or Ni100 sensor connection | 2, 3 or 4-wire, programmable |
Pt100 or Ni100 connection resistance (2 and 3-wire) Pt100 lub Ni100 | <10 Ω (each wire) |
Maximum resistance for 2-wire connection which can be corrected with software | 0,00 …20,00 Ω (sum of both wires) |
Bias current of Pt100 or Ni100 sensors | < 0,25mA |
Compencation of thermocouple cold junction | I:internal or E:external, programmable |
Maximum error of thermocouple cold junction internal compensation | ±1 °C |
Temperature range of thermocouple cold junction external compensation | -50,0 … 100,0 °C, programmaable |
Range of temperature offset | ±10,0 °C, programmable |
Galvanic insulation between input and output terminals | 500 V AC |
Output signal | N: 0-10 V or I:10-0 V, programmable |
Linear region of output signal | 0 … 10,3 V |
Output signal delay after power on | ca. 5 s |
Digital filter time constant (1st order filter) | 0,2; 1; 2; 4; 8; 16; 32 s, programmable |
Sensor failure indication | L:0 or H:11,5 V, programmable |
Power supply | 14 … 36 V DC / 18 mA |
Ambient temperature | -20 … +70 °C |
Dimensions (diameter x height) / weight | 44 x 21 mm / ca. 50 g |